project
|
Standard
|
Power Supply
|
Rated input voltage
|
Three-phase 380V±30%,50~60Hz±5%
|
output
|
Rated output voltage
|
Three-phase 380V (maximum output voltage is the same as input supply voltage) |
Continuous running current
|
100% rated output current |
Overload capacity
|
150% rated output current for 2 minutes and 180% rated output current for 10 seconds |
control performance
|
output frequency
|
0Hz~400Hz
|
modulation mode
|
Optimizing Space Voltage Vector PWM Modulation Mode |
control mode
|
Vector control with PG feedback; vector control without PG feedback; V/F control |
Running commands in a given way
|
The keyboard is given; the external terminal is given; it is given by the host computer through the serial communication port. |
Speed Setting Resolution
|
Digital Settings: 0.01Hz
Analog Settings: 1/1000 Maximum Frequency |
Speed setting accuracy
|
Digital Setting: +0.01% Maximum Frequency (-10 +40)
Simulated setting: +0.05% maximum frequency (25 +10)
|
Speed control accuracy
|
Vector control with PG feedback: +0.05% rated speed;
(25 C + 10 C)
No PG feedback vector control: +0.5% rated speed;
(25 C + 10 C) |
Speed control range
|
Vector control with PG feedback: 1:1000
PG-free feedback vector control: 1:100 |
Torque control response
|
Vector control with PG feedback: <150 mS
No PG Feedback Vector Control: <200 mS |
Starting torque
|
Vector control with PG feedback: 200% rated output torque / 0.05Hz; vector control without PG feedback: 150% rated output torque / 0.5Hz |
Braking torque
|
Energy-free braking: rated output speed less than 22KW > 20%
Torque, above 30KW > 15% rated output torque
Energy Consumption Braking: > 150% Rated Output Torque |
Torque control accuracy
|
Rated Output Torque (+5%)
|
Control Input and Output Signals
|
Setting Reference Voltage Output
|
1 way, +10V, 5mA
|
Control Voltage Source Output
|
24 V, 100 mA; can also be provided by the outside through the PLC terminal
|
External user power input
|
1 way, the working power supply of the contact input terminal can use the power supply of the external active contacts (12 ~ 24V) |
Analog input
|
1 way,0~10 V /0~20 mA DC,10bit
1 way,0~10 V DC,10bit
|
Analog output
|
1 way, 0 ~ 10V, output programmable, multiple output options
1-way, 0-10V/0-20mA, output programmable, multiple output options
|
Programmable Contact Input
|
7-way programmable, forward/reverse, forward/reverse point movement, multi-segment speed, multi-segment acceleration/deceleration time, free parking, voltage/current switching and other 27 functions are optional. |
Pulse signal input
|
1 way,0~50K HZ
|
PG signal input
|
A+, A-, B+, B-differential input; A-, B-open collector disc input
|
FAM Frequency Signal Output
|
1 channel, frequency meter signal (output frequency is multiple signal of frequency converter output frequency), 0-50 kHz
|
Collector open circuit output
|
2 channels, 24 operation states are optional; maximum output current is 50mA
|
Programmable Relay Output
|
Two paths, 24 operating states are optional, contact capacity: 250V AC/3A or 30V DC/1A
|
Serial communication interface
|
RS-485 interface
|
Standard function
|
Current Limit, Torque Lift, Speed Tracking, DC Braking, Power Outage Restart, Slip Compensation, Fault Auto-Reset, Frequency Limit, Bias Frequency, Start Frequency, Jump Frequency, Frequency Gain, Carrier Frequency Adjustment, Acceleration/Deceleration Mode Adjustable, Voltmeter Output, Amperometer Output, Multi-Section Speed, Range Sequential operation, swing frequency operation, PI closed-loop operation, proportional linkage, long-distance control, positive and negative dead zone
|
Protection function
|
Overvoltage, undervoltage, overcurrent, current limit, overload, overheat, electronic thermal overload relay, overvoltage stall, data protection, etc.
|
display
|
Four-digit Digital Display (LED)
|
Setting 16 state parameters such as frequency, output frequency, output voltage, output current, motor speed, output torque, switching terminal, programming menu parameters and 31 fault codes, etc.
|
Chinese/English LCD
|
Control mode, current programming or monitoring parameter name, alarm content, keyboard operation guidance, etc.
|
Indicator light
(LED)
|
Units of parameters, RUN/STOP status, etc.
|
Conditions of use
|
Installation site
|
Indoor, no more than 1000 meters above sea level, no dust, no corrosive gas, no direct sunlight
|
Applicable environment
|
- 10 +40 (bare machine is -10 +50), 20%~90% RH (no condensation)
|
Vibration
|
小于0.5g
|
Storage mode
|
-25℃~+65℃
|
Installation mode
|
Wall-mounted, floor-mounted electronic control cabinet
|
Protection level
|
IP20
|
Cooling mode
|
0.75KW and below are closed self-cooling, others are forced air-cooling.
|